01981 242100

Dean Forge

Clear Vision of Fire

Dean Clearburn stoves incorporate a preheated air wash system. This system is designed to heat the secondary air to a very high temperature before being drawn over the glass.

The stove induces pre-heated air from the bottom of the stove through a labyrinth of passages into the top of the stove and over the double glazed door, this drives unburnt gasses back into the fire chamber mixing with the air at the same time.

These gasses combined with the hot air cause combustion over the glass, burning more fuel particles and unwanted deposits off the glass; thus increasing the efficiency and vision of the fire.

 

Dean Stoves Dartmoor 5Kw

Dean Stoves Dartmoor 5Kw

The Dartmoor 5 is our smallest wood burning and multi-fuel stove and yet is big on features.

Dean Stoves Dartmoor 5Kw

This compact, robust fire incorporates a straightforward air wash system providing clean glass, with a 'spinning' primary air control, to give direct control over the burning rate.

The options of an easily fitted drop-in riddling grate and heat deflector shields, completes a great all round specification for this superb little 5 Kw stove.

Dean Stoves Croft Slimline 6.5Kw

Dean Stoves Croft Slimline 6.5Kw

The Croft Junior wood burning and multi-fuel stove is designed on simple clean-cut lines with the advantage of a flat heating area on top.

Dean Stoves Croft Slimline 6.5Kw
 
Nominal Output 5Kw
Efficiency 83%
Flue Size 125mm (5")
Standard Leg Length 100mm (4")
Optional Integral Boiler No
Optional Saddle Boiler No
Optional Flat Back Boiler 9,000BTU
Flue Centre Top 100mm
Flue Centre Rear 485mm

 

Dean Stoves Croft Slimline 6.5Kw

Dean Stoves Croft Slimline 6.5Kw

The Croft Slimline wood burning and multi-fuel stove is effectively the same stove as the Croft Small with reduced depth.

Dean Stoves Croft Slimline 6.5Kw
Nominal Output 6.5Kw
Efficiency 79.6%
Flue Size 150mm (6")
Standard Leg Length 100mm (4")
Optional Integral Boiler No
Optional Saddle Boiler No
Optional Flat Back Boiler 9,000BTU
Flue Centre Top 110mm
Flue Centre Rear 470mm

 

Dean Stoves Croft Small 8Kw

Dean Stoves Croft Small 8Kw

The Croft Small wood burning and multi-fuel stove is designed on simple clean-cut lines with the advantage of a flat heating area on top.

Dean Stoves Croft Small 8Kw
Nominal Output 8Kw
Efficiency 76.4%
Flue Size 150mm (6")
Standard Leg Length 100mm (4")
Optional Integral Boiler No
Optional Saddle Boiler 18,000BTU
Optional Flat Back Boiler 10,000BTU
Flue Centre Top 110mm
Flue Centre Rear 470mm

 

Dean Stoves Croft Medium 11Kw

Dean Stoves Croft Medium 11Kw

The Croft Medium wood burning and multi-fuel stove is designed on simple clean-cut lines with the advantage of a flat heating area on top.

Dean Stoves Croft Medium 11Kw
Nominal Output 11Kw
Efficiency 75.9%
Flue Size 150mm (6")
Standard Leg Length 150mm (6")
Optional Integral Boiler 30,000BTU
Optional Saddle Boiler 25,000BTU
Optional Flat Back Boiler 10,000BTU
Flue Centre Top 110mm
Flue Centre Rear 525mm

 

Dean Stoves Croft Large 12.5 Kw

Dean Stoves Croft Large 12.5 Kw

The Croft Large wood burning and multi-fuel stove is designed on simple clean-cut lines with the advantage of a flat heating area on top.

Dean Stoves Croft Large 12.5 Kw
Nominal Output 12.5 Kw
Efficiency 75.9%
Flue Size 150mm (6")
Standard Leg Length 150mm (6")
Optional Integral Boiler 32,000BTU
Optional Saddle Boiler 27,000BTU
Optional Flat Back Boiler 10,000BTU
Flue Centre Top 110mm
Flue Centre Rear 525mm

 

Dean Stoves Croft Junior Logstore 5Kw

Dean Stoves Croft Junior Logstore 5Kw

The Croft Junior Logstore wood burning and multi-fuel stove is a taller version of the Croft Junior model.

Dean Stoves Croft Junior Logstore 5Kw
Nominal Output 5Kw
Efficiency 83%
Flue Size 125mm (5")
Standard Leg Length n/a
Optional Integral Boiler No
Optional Saddle Boiler No
Optional Flat Back Boiler 9,000BTU
Flue Centre Top 100mm
Flue Centre Rear 698mm

 

Dean Stoves Croft Small Logstore 8Kw

Dean Stoves Croft Small Logstore 8Kw

The Croft Small Logstore wood burning and multi-fuel stove is a taller version of the Croft Small model.

Dean Stoves Croft Small Logstore 8Kw
Nominal Output 8Kw
Efficiency 76.4%
Flue Size 150mm (6")
Standard Leg Length n/a
Optional Integral Boiler No
Optional Saddle Boiler 18,000BTU
Optional Flat Back Boiler 10,000BTU
Flue Centre Top 110mm
Flue Centre Rear 745mm

 

Dean Stoves Herrick Junior 5Kw

Dean Stoves Herrick Junior 5Kw

There are two versions of the Herrick Junior wood burning and multi-fuel stove, the Herrick Junior Low and the Herrick Junior High. 

Dean Stoves Herrick Junior 5Kw
Nominal Output 5Kw
Efficiency 83%
Flue Size 125mm (5")
Standard Leg Length 100mm (4")
Optional Integral Boiler No
Optional Saddle Boiler No
Optional Flat Back Boiler 9,000BTU
Flue Centre Top 100mm
Flue Centre Rear 485mm

 

Dean Stoves Herrick Small 8Kw

Dean Stoves Herrick Small 8Kw

There are two versions of the Herrick Small wood burning and multi-fuel stove, the Herrick Small Low and the Herrick Small High.

Dean Stoves Herrick Small 8Kw
Nominal Output 8Kw
Efficiency 76.4%
Flue Size 150mm (6")
Standard Leg Length 100mm (4")
Optional Integral Boiler No
Optional Saddle Boiler 18,000BTU
Optional Flat Back Boiler 10,000BTU
Flue Centre Top 110mm
Flue Centre Rear 470mm

 

Dean Stoves Herrick Medium 11Kw

Dean Stoves Herrick Medium 11Kw

There are two versions of the Herrick Medium wood burnng and multi-fuel stove, the Herrick Medium Low and the Herrick Medium High.

Dean Stoves Herrick Medium 11Kw
Nominal Output 11Kw
Efficiency 75.9%
Flue Size 150mm (6")
Standard Leg Length 150mm (6")
Optional Integral Boiler 30,000BTU
Optional Saddle Boiler 25,000BTU
Optional Flat Back Boiler 10,000BTU
Flue Centre Top 110mm
Flue Centre Rear 525mm

 

Dean Stoves Herrick Large 12.5 Kw

Dean Stoves Herrick Large 12.5 Kw

There are two versions of the Herrick Large wood burning and multi-fuel stove, the Herrick Large Low and the Herrick Large High.

Dean Stoves Herrick Large 12.5 Kw
Nominal Output 12.5 Kw
Efficiency 75.9%
Flue Size 150mm (6")
Standard Leg Length 150mm (6")
Optional Integral Boiler 32,000BTU
Optional Saddle Boiler 27,000BTU
Optional Flat Back Boiler 10,000BTU
Flue Centre Top 110mm
Flue Centre Rear 525mm

 

Dean Stoves Herrick Inset

Dean Stoves Herrick Inset

Incorporating all the features of the Croft Clearburn range, this great little inset woodburning and multifuel stove has been designed to fir into an existing fireplace.

Dean Stoves Herrick Inset

Nominal Output 5Kw
Efficiency 82.1%
Flue Outlet 125mm (5")

Information & Options

Legs

All Junior, Slimline and Small Clearburn stoves are fitted with 100mm (4") legs and all Clearburn stoves in the medium and largeranges are fitted with 150mm (6") legs as standard giving their standard height in the tables.

We are able to offer variation in leg height from 25mm (1") to 200mm
(8"), please state this when ordering your stove.

Flue Options

There are three flue arrangements available – top, rear and back box. Top and rear options are fitted as standard to all Dean Stoves Clearburn stoves; this is achieved by a moving and interchangeable flue spigot and cover plate to either the top or the back.

The back box (see illustration) is an optional extra, this is fixed to the back outlet on the stove, using the same fixing point as the standard spigot, and enabling the stove to be brought forward in the fireplace and the top kept clear, whilst using a vertical flue. This option also eliminates the use of a tee and cap, with the added facility in most cases to still clean the flue through the stove. Please note: cleaning the flue through the stove is not always possible with saddle and integral boilers.
Multi-Fuel Grates Option

The full range of Clearburn stoves can be fitted with a multi-fuel coal grate. The Junior, Slimline and Small can be fitted with a grate system where you can riddle the ash through to an ash pan via an external riddling arm. The Medium, Large and Double-sided stoves have a static grate system. All these options can be removed for greater efficiency when burning wood.

Double Sided Stoves

Most of our stoves are able to be manufactured as double sided with an opening door on both sides.

Please note: it is not always possible to open both doors at the same time, this will depend on the stove size and the flue draught.

Croft Clearburn Top Options

All Croft Clearburn stoves have the option of a profiled flat top or a rolled edge flat top. As with all the Clearburn range, options of cage or bar door handles and black or brass secondary air control knobs are available.

Heating Requirement

A good rule of thumb guide to calculate the heat requirement of a given room is:

HEIGHT X WIDTH X DEPTH (in feet) divided by 500 (for metres divide by 14)

This gives you the kilowatt requirement. Multiply this result by 3,400 to get the BTUs requirement. This is based on average house insulation with room temperatures of 20°C and an ambient temperature of -1°C. Well-insulated houses could replace the division of 500 with 650.

Fuel

All stoves will burn wood, peat and brickettes. Stoves fitted with multi-fuel grates will burn all types of smokeless fuel recommended for enclosed appliances. As with all woodburning stoves the wood you burn must have a moisture content of less than 20%. It is imperative the wood you use should have at least one.

Legs

All Junior, Slimline and Small Clearburn stoves are fitted with 100mm (4") legs and all Clearburn stoves in the medium and largeranges are fitted with 150mm (6") legs as standard giving their standard height in the tables.

We are able to offer variation in leg height from 25mm (1") to 200mm (8"), please state this when ordering your stove.

Flue Options

There are three flue arrangements available – top, rear and back box. Top and rear options are fitted as standard to all Dean Stoves Clearburn stoves; this is achieved by a moving and interchangeable flue spigot and cover plate to either the top or the back.

The back box (see illustration) is an optional extra, this is fixed to the back outlet on the stove, using the same fixing point as the standard spigot, and enabling the stove to be brought forward in the fireplace and the top kept clear, whilst using a vertical flue. This option also eliminates the use of a tee and cap, with the added facility in most cases to still clean the flue through the stove. Please note: cleaning the flue through the stove is not always possible with saddle and integral boilers.

Closed Combustion (Woodburning only)

The Clearburn Range (excluding the Clearburn Inset and Logstore Stoves) can be fitted with a direct air manifold enabling combustion air to be connected directly to an outside air source. By using the Closed Combustion system you prevent the stove from stealing heat from the room thus maximising the heat efficiency of the stove. The Closed Combustion manifold fits neatly to the underside of a standard or long legged Clearburn stove.